rajbly
08-27-2001, 03:43 AM
hello sir,
please help me
i have two systems. one system connected internet]
through dial up modem and another one connected internet through
cabel modem.
& i have 3 code below for checking internet
but 1 & 3 codes checking first system only
1 & 3 codes are not checked second system
in second system every time they showing offline.
the 2 code not working in both system.
please help me.
1.
A call to the function IsConnected() returns true if you are connected, and false if youre not.
On your form, place a cmd button and put this command behind it.
Private Sub Command1_Click()
if IsConnected = true then
MsgBox "Connected"
else
MsgBox "Not Connected"
End If
End Sub
in the decalrations section place this code:
Private Declare Function RasEnumConnections Lib "RasApi32.dll" Alias "RasEnumConnectionsA" (lpRasCon As Any, lpcb As Long, lpcConnections As Long) As Long
Private Declare Function RasGetConnectStatus Lib "RasApi32.dll" Alias "RasGetConnectStatusA" (ByVal hRasCon As Long, lpStatus As Any) As Long
'
Private Const RAS95_MaxEntryName = 256
Private Const RAS95_MaxDeviceType = 16
Private Const RAS95_MaxDeviceName = 32
'
Private Type RASCONN95
dwSize As Long
hRasCon As Long
szEntryName(RAS95_MaxEntryName) As Byte
szDeviceType(RAS95_MaxDeviceType) As Byte
szDeviceName(RAS95_MaxDeviceName) As Byte
End Type
'
Private Type RASCONNSTATUS95
dwSize As Long
RasConnState As Long
dwError As Long
szDeviceType(RAS95_MaxDeviceType) As Byte
szDeviceName(RAS95_MaxDeviceName) As Byte
End Type
'A call to the function IsConnected returns true if the computer has established a connection to the internet.
Private Function IsConnected() As Boolean
Dim TRasCon(255) As RASCONN95
Dim lg As Long
Dim lpcon As Long
Dim RetVal As Long
Dim Tstatus As RASCONNSTATUS95
'
TRasCon(0).dwSize = 412
lg = 256 * TRasCon(0).dwSize
'
RetVal = RasEnumConnections(TRasCon(0), lg, lpcon)
If RetVal <> 0 Then
MsgBox "ERROR"
Exit Function
End If
'
Tstatus.dwSize = 160
RetVal = RasGetConnectStatus(TRasCon(0).hRasCon, Tstatus)
If Tstatus.RasConnState = &H2000 Then
IsConnected = True
Else
IsConnected = False
End If
End Function
2.
If you are designing a project which can use an Internet connection, it can be useful to know whether the system is connected or not. There are various methods of doing this, however the most informative and reliable method is to use the WinInet.DLL InternetGetConnectedStateEx() API call. The only problem with this call is it is only implemented for the WinInet.DLL version shipped with Internet Explorer version 4.0 or higher.
To test out this function, start a new project and add the following code:
Private Declare Function InternetGetConnectedStateEx Lib "wininet.dll" Alias "InternetGetConnectedStateExA" _
(ByRef lpdwFlags As Long, _
ByVal lpszConnectionName As String, _
ByVal dwNameLen As Long, _
ByVal dwReserved As Long _
) As Long
Private Enum EIGCInternetConnectionState
INTERNET_CONNECTION_MODEM = &H1&
INTERNET_CONNECTION_LAN = &H2&
INTERNET_CONNECTION_PROXY = &H4&
INTERNET_RAS_INSTALLED = &H10&
INTERNET_CONNECTION_OFFLINE = &H20&
INTERNET_CONNECTION_CONFIGURED = &H40&
End Enum
Private Property Get InternetConnected( _
Optional ByRef eConnectionInfo As EIGCInternetConnectionState, _
Optional ByRef sConnectionName As String _
) As Boolean
Dim dwFlags As Long
Dim sNameBuf As String
Dim lR As Long
Dim iPos As Long
sNameBuf = String$(513, 0)
lR = InternetGetConnectedStateEx(dwFlags, sNameBuf, 512, 0&)
eConnectionInfo = dwFlags
iPos = InStr(sNameBuf, vbNullChar)
If iPos > 0 Then
sConnectionName = Left$(sNameBuf, iPos - 1)
ElseIf Not sNameBuf = String$(513, 0) Then
sConnectionName = sNameBuf
End If
InternetConnected = (lR = 1)
End Property
To try out the code, add a CommandButton and a Multi-Line TextBox to your test project's main form. Then add the following code to try the function:
Private Sub Command1_Click()
Dim eR As EIGCInternetConnectionState
Dim sMsg As String
Dim sName As String
Dim bConnected As Boolean
' Determine whether we have a connection:
bConnected = InternetConnected(eR, sName)
' The connection state info parameter provides details
' about how we connect:
If (eR And INTERNET_CONNECTION_MODEM) = INTERNET_CONNECTION_MODEM Then
sMsg = sMsg & "Connection uses a modem." & vbCrLf
End If
If (eR And INTERNET_CONNECTION_LAN) = INTERNET_CONNECTION_LAN Then
sMsg = sMsg & "Connection uses LAN." & vbCrLf
End If
If (eR And INTERNET_CONNECTION_PROXY) = INTERNET_CONNECTION_PROXY Then
sMsg = sMsg & "Connection is via Proxy." & vbCrLf
End If
If (eR And INTERNET_CONNECTION_OFFLINE) = INTERNET_CONNECTION_OFFLINE Then
sMsg = sMsg & "Connection is Off-line." & vbCrLf
End If
If (eR And INTERNET_CONNECTION_CONFIGURED) = INTERNET_CONNECTION_CONFIGURED Then
sMsg = sMsg & "Connection is Configured." & vbCrLf
Else
sMsg = sMsg & "Connection is Not Configured." & vbCrLf
End If
If (eR And INTERNET_RAS_INSTALLED) = INTERNET_RAS_INSTALLED Then
sMsg = sMsg & "System has RAS installed." & vbCrLf
End If
' Display the connection name and info:
If bConnected Then
Text1.Text = "Connected: " & sName & vbCrLf & vbCrLf & sMsg
Else
Text1.Text = "Not Connected: " & sName & vbCrLf & vbCrLf & sMsg
End If
End Sub
Run the project. When you click the command button, the text box will be updated with the status of the current connection, the name of RAS dial-up connection used (if applicable) and also various information about how the connection is being achieved (i.e. by modem or LAN, via a proxy and whether the connection is configured or not).
3.
Option Explicit
Private Const ERROR_SUCCESS = 0&
Private Const APINULL = 0&
Private Const HKEY_LOCAL_MACHINE = &H80000002
Private Const RAS_MAXENTRYNAME As Integer = 256
Private Const RAS_MAXDEVICETYPE As Integer = 16
Private Const RAS_MAXDEVICENAME As Integer = 128
Private Const RAS_RASCONNSIZE As Integer = 412
Private ReturnCode As Long
Private Declare Function RegCloseKey Lib "advapi32.dll" (ByVal hKey As Long) As Long
Private Declare Function RegOpenKey Lib "advapi32.dll" Alias "RegOpenKeyA" (ByVal hKey As Long, ByVal lpSubKey As String, phkResult As Long) As Long
Private Declare Function RegQueryValueEx Lib "advapi32.dll" Alias "RegQueryValueExA" (ByVal hKey As Long, ByVal lpValueName As String, ByVal lpReserved As Long, lpType As Long, lpData As Any, lpcbData As Long) As Long
Private Declare Function RasEnumConnections Lib "rasapi32.dll" Alias "RasEnumConnectionsA" (lpRasConn As Any, lpcb As Long, lpcConnections As Long) As Long
Private Declare Function RasHangUp Lib "rasapi32.dll" Alias "RasHangUpA" (ByVal hRasConn As Long) As Long
Private Type RasEntryName
dwSize As Long
szEntryName(RAS_MAXENTRYNAME) As Byte
End Type
Private Type RasConn
dwSize As Long
hRasConn As Long
szEntryName(RAS_MAXENTRYNAME) As Byte
szDeviceType(RAS_MAXDEVICETYPE) As Byte
szDeviceName(RAS_MAXDEVICENAME) As Byte
End Type
Public gstrISPName As String
Public Function ActiveConnection() As Boolean
Dim hKey As Long
Dim lpSubKey As String
Dim phkResult As Long
Dim lpValueName As String
Dim lpReserved As Long
Dim lpType As Long
Dim lpData As Long
Dim lpcbData As Long
ActiveConnection = False
lpSubKey = "System\CurrentControlSet\Services\RemoteAccess"
ReturnCode = RegOpenKey(HKEY_LOCAL_MACHINE, lpSubKey, phkResult)
If ReturnCode = ERROR_SUCCESS Then
hKey = phkResult
lpValueName = "Remote Connection"
lpReserved = APINULL
lpType = APINULL
lpData = APINULL
lpcbData = APINULL
ReturnCode = RegQueryValueEx(hKey, lpValueName, lpReserved, lpType, ByVal lpData, lpcbData)
lpcbData = Len(lpData)
ReturnCode = RegQueryValueEx(hKey, lpValueName, lpReserved, lpType, lpData, lpcbData)
If ReturnCode = ERROR_SUCCESS Then
If lpData = 0 Then
ActiveConnection = False
Else
ActiveConnection = True
End If
End If
RegCloseKey (hKey)
End If
End Function
Private Sub cmdCheck_Click()
If ActiveConnection = True Then
MsgBox "Internet Connection Found!", vbInformation + vbOKOnly
Else
MsgBox "Internet Connection NOT Found!", vbCritical + vbOKOnly
End If
End Sub
thank you ,
rajbly
please help me
i have two systems. one system connected internet]
through dial up modem and another one connected internet through
cabel modem.
& i have 3 code below for checking internet
but 1 & 3 codes checking first system only
1 & 3 codes are not checked second system
in second system every time they showing offline.
the 2 code not working in both system.
please help me.
1.
A call to the function IsConnected() returns true if you are connected, and false if youre not.
On your form, place a cmd button and put this command behind it.
Private Sub Command1_Click()
if IsConnected = true then
MsgBox "Connected"
else
MsgBox "Not Connected"
End If
End Sub
in the decalrations section place this code:
Private Declare Function RasEnumConnections Lib "RasApi32.dll" Alias "RasEnumConnectionsA" (lpRasCon As Any, lpcb As Long, lpcConnections As Long) As Long
Private Declare Function RasGetConnectStatus Lib "RasApi32.dll" Alias "RasGetConnectStatusA" (ByVal hRasCon As Long, lpStatus As Any) As Long
'
Private Const RAS95_MaxEntryName = 256
Private Const RAS95_MaxDeviceType = 16
Private Const RAS95_MaxDeviceName = 32
'
Private Type RASCONN95
dwSize As Long
hRasCon As Long
szEntryName(RAS95_MaxEntryName) As Byte
szDeviceType(RAS95_MaxDeviceType) As Byte
szDeviceName(RAS95_MaxDeviceName) As Byte
End Type
'
Private Type RASCONNSTATUS95
dwSize As Long
RasConnState As Long
dwError As Long
szDeviceType(RAS95_MaxDeviceType) As Byte
szDeviceName(RAS95_MaxDeviceName) As Byte
End Type
'A call to the function IsConnected returns true if the computer has established a connection to the internet.
Private Function IsConnected() As Boolean
Dim TRasCon(255) As RASCONN95
Dim lg As Long
Dim lpcon As Long
Dim RetVal As Long
Dim Tstatus As RASCONNSTATUS95
'
TRasCon(0).dwSize = 412
lg = 256 * TRasCon(0).dwSize
'
RetVal = RasEnumConnections(TRasCon(0), lg, lpcon)
If RetVal <> 0 Then
MsgBox "ERROR"
Exit Function
End If
'
Tstatus.dwSize = 160
RetVal = RasGetConnectStatus(TRasCon(0).hRasCon, Tstatus)
If Tstatus.RasConnState = &H2000 Then
IsConnected = True
Else
IsConnected = False
End If
End Function
2.
If you are designing a project which can use an Internet connection, it can be useful to know whether the system is connected or not. There are various methods of doing this, however the most informative and reliable method is to use the WinInet.DLL InternetGetConnectedStateEx() API call. The only problem with this call is it is only implemented for the WinInet.DLL version shipped with Internet Explorer version 4.0 or higher.
To test out this function, start a new project and add the following code:
Private Declare Function InternetGetConnectedStateEx Lib "wininet.dll" Alias "InternetGetConnectedStateExA" _
(ByRef lpdwFlags As Long, _
ByVal lpszConnectionName As String, _
ByVal dwNameLen As Long, _
ByVal dwReserved As Long _
) As Long
Private Enum EIGCInternetConnectionState
INTERNET_CONNECTION_MODEM = &H1&
INTERNET_CONNECTION_LAN = &H2&
INTERNET_CONNECTION_PROXY = &H4&
INTERNET_RAS_INSTALLED = &H10&
INTERNET_CONNECTION_OFFLINE = &H20&
INTERNET_CONNECTION_CONFIGURED = &H40&
End Enum
Private Property Get InternetConnected( _
Optional ByRef eConnectionInfo As EIGCInternetConnectionState, _
Optional ByRef sConnectionName As String _
) As Boolean
Dim dwFlags As Long
Dim sNameBuf As String
Dim lR As Long
Dim iPos As Long
sNameBuf = String$(513, 0)
lR = InternetGetConnectedStateEx(dwFlags, sNameBuf, 512, 0&)
eConnectionInfo = dwFlags
iPos = InStr(sNameBuf, vbNullChar)
If iPos > 0 Then
sConnectionName = Left$(sNameBuf, iPos - 1)
ElseIf Not sNameBuf = String$(513, 0) Then
sConnectionName = sNameBuf
End If
InternetConnected = (lR = 1)
End Property
To try out the code, add a CommandButton and a Multi-Line TextBox to your test project's main form. Then add the following code to try the function:
Private Sub Command1_Click()
Dim eR As EIGCInternetConnectionState
Dim sMsg As String
Dim sName As String
Dim bConnected As Boolean
' Determine whether we have a connection:
bConnected = InternetConnected(eR, sName)
' The connection state info parameter provides details
' about how we connect:
If (eR And INTERNET_CONNECTION_MODEM) = INTERNET_CONNECTION_MODEM Then
sMsg = sMsg & "Connection uses a modem." & vbCrLf
End If
If (eR And INTERNET_CONNECTION_LAN) = INTERNET_CONNECTION_LAN Then
sMsg = sMsg & "Connection uses LAN." & vbCrLf
End If
If (eR And INTERNET_CONNECTION_PROXY) = INTERNET_CONNECTION_PROXY Then
sMsg = sMsg & "Connection is via Proxy." & vbCrLf
End If
If (eR And INTERNET_CONNECTION_OFFLINE) = INTERNET_CONNECTION_OFFLINE Then
sMsg = sMsg & "Connection is Off-line." & vbCrLf
End If
If (eR And INTERNET_CONNECTION_CONFIGURED) = INTERNET_CONNECTION_CONFIGURED Then
sMsg = sMsg & "Connection is Configured." & vbCrLf
Else
sMsg = sMsg & "Connection is Not Configured." & vbCrLf
End If
If (eR And INTERNET_RAS_INSTALLED) = INTERNET_RAS_INSTALLED Then
sMsg = sMsg & "System has RAS installed." & vbCrLf
End If
' Display the connection name and info:
If bConnected Then
Text1.Text = "Connected: " & sName & vbCrLf & vbCrLf & sMsg
Else
Text1.Text = "Not Connected: " & sName & vbCrLf & vbCrLf & sMsg
End If
End Sub
Run the project. When you click the command button, the text box will be updated with the status of the current connection, the name of RAS dial-up connection used (if applicable) and also various information about how the connection is being achieved (i.e. by modem or LAN, via a proxy and whether the connection is configured or not).
3.
Option Explicit
Private Const ERROR_SUCCESS = 0&
Private Const APINULL = 0&
Private Const HKEY_LOCAL_MACHINE = &H80000002
Private Const RAS_MAXENTRYNAME As Integer = 256
Private Const RAS_MAXDEVICETYPE As Integer = 16
Private Const RAS_MAXDEVICENAME As Integer = 128
Private Const RAS_RASCONNSIZE As Integer = 412
Private ReturnCode As Long
Private Declare Function RegCloseKey Lib "advapi32.dll" (ByVal hKey As Long) As Long
Private Declare Function RegOpenKey Lib "advapi32.dll" Alias "RegOpenKeyA" (ByVal hKey As Long, ByVal lpSubKey As String, phkResult As Long) As Long
Private Declare Function RegQueryValueEx Lib "advapi32.dll" Alias "RegQueryValueExA" (ByVal hKey As Long, ByVal lpValueName As String, ByVal lpReserved As Long, lpType As Long, lpData As Any, lpcbData As Long) As Long
Private Declare Function RasEnumConnections Lib "rasapi32.dll" Alias "RasEnumConnectionsA" (lpRasConn As Any, lpcb As Long, lpcConnections As Long) As Long
Private Declare Function RasHangUp Lib "rasapi32.dll" Alias "RasHangUpA" (ByVal hRasConn As Long) As Long
Private Type RasEntryName
dwSize As Long
szEntryName(RAS_MAXENTRYNAME) As Byte
End Type
Private Type RasConn
dwSize As Long
hRasConn As Long
szEntryName(RAS_MAXENTRYNAME) As Byte
szDeviceType(RAS_MAXDEVICETYPE) As Byte
szDeviceName(RAS_MAXDEVICENAME) As Byte
End Type
Public gstrISPName As String
Public Function ActiveConnection() As Boolean
Dim hKey As Long
Dim lpSubKey As String
Dim phkResult As Long
Dim lpValueName As String
Dim lpReserved As Long
Dim lpType As Long
Dim lpData As Long
Dim lpcbData As Long
ActiveConnection = False
lpSubKey = "System\CurrentControlSet\Services\RemoteAccess"
ReturnCode = RegOpenKey(HKEY_LOCAL_MACHINE, lpSubKey, phkResult)
If ReturnCode = ERROR_SUCCESS Then
hKey = phkResult
lpValueName = "Remote Connection"
lpReserved = APINULL
lpType = APINULL
lpData = APINULL
lpcbData = APINULL
ReturnCode = RegQueryValueEx(hKey, lpValueName, lpReserved, lpType, ByVal lpData, lpcbData)
lpcbData = Len(lpData)
ReturnCode = RegQueryValueEx(hKey, lpValueName, lpReserved, lpType, lpData, lpcbData)
If ReturnCode = ERROR_SUCCESS Then
If lpData = 0 Then
ActiveConnection = False
Else
ActiveConnection = True
End If
End If
RegCloseKey (hKey)
End If
End Function
Private Sub cmdCheck_Click()
If ActiveConnection = True Then
MsgBox "Internet Connection Found!", vbInformation + vbOKOnly
Else
MsgBox "Internet Connection NOT Found!", vbCritical + vbOKOnly
End If
End Sub
thank you ,
rajbly